1.
Braz. dent. j ; 24(2): 147-151, Mar-Apr/2013. tab, graf
Article in English | LILACS | ID: lil-675660

ABSTRACT

Lack of passivity has been associated with biomechanical problems in implant-supported prosthesis. The aim of this study was to evaluate the passivity of three techniques to fabricate an implant framework from a Co-Cr alloy by photoelasticity. The model was obtained from a steel die simulating an edentulous mandible with 4 external hexagon analog implants with a standard platform. On this model, five frameworks were fabricated for each group: a monoblock framework (control), laser and TIG welding frameworks. The photoelastic model was made from a flexible epoxy resin. On the photoelastic analysis, the frameworks were bolted onto the model for the verification of maximum shear stress at 34 selected points around the implants and 5 points in the middle of the model. The stresses were compared all over the photoelastic model, between the right, left, and center regions and between the cervical and apical regions. The values were subjected to two-way ANOVA, and Tukey's test (α=0.05). There was no significant difference among the groups and studied areas (p>0.05). It was concluded that the stresses generated around the implants were similar for all techniques.


Resumo A falta de passividade tem sido associada a problemas biomecânicos em próteses implantossuportadas. A proposta deste estudo foi avaliar, por meio da fotoelasticidade, a influência de três diferentes de fabricação de infraestrutura em liga de Co-Cr na passividade destas. O modelo foi obtido a partir de uma matriz de aço simulando uma mandíbula edêntula com 4 análogos de implantes de hexágono externo com plataforma padrão. Neste modelo, foram confeccionados cinco amostras para cada grupo: infraestruturas em monobloco, infraestruturas soldadas a laser e soldadas a TIG. O modelo fotoelástico foi feito com uma resina epóxi flexível (GIII, Polipox Industria e Comercio Ltda.). Na análise fotoelástica, as infraestruturas foram aparafusadas no modelo para a verificação da tensão de cisalhante máxima em 34 pontos selecionados ao redor dos implantes e 5 pontos na região média do modelo. Foram comparadas as tensões em todo o modelo fotoelástico, entre as regiões direita, esquerda e centro e também entre as regiões cervical e apical. Os valores foram submetidos à análise de variância a dois critérios, seguido pelo teste de Tukey (α=0,05). Os resultados não mostraram diferença significativa entre as tensões presentes nos grupos e nas áreas estudadas. Conclui-seque as tensões geradas ao redor dos implantes foram semelhantes entre as diferentes técnicas de confecção e entre todas as regiões analisadas. .


Subject(s)
Humans , Chromium Alloys/chemistry , Dental Prosthesis, Implant-Supported , Dental Soldering/methods , Lasers , Plasma Gases , Dental Casting Technique , Dental Implant-Abutment Design , Dental Implants , Models, Dental , Dental Soldering/instrumentation , Epoxy Resins/chemistry , Jaw, Edentulous/rehabilitation , Materials Testing , Mandible/pathology , Stress, Mechanical , Surface Properties , Welding/instrumentation , Welding/methods
2.
Odonto (Säo Bernardo do Campo) ; 20(39): 81-87, jan.-jun. 2012. ilus
Article in Portuguese | LILACS, BBO | ID: lil-790164

ABSTRACT

Objetivo: avaliar por meio da fotoelasticidade, as tensões geradas ao redor de implantes após o aparafusamento de estruturas confeccionadas por soldagem a Laser ou a TIG de barras cilíndricas de Cobalto-Cromo. Metodologia: foi realizado um estudo experimental a partir de um modelo de trabalho com dois implantes rosqueáveis. Nele foram realizadas a união dos UCLAs calcináveis à barra metálica, ambos de Cobalto-Cromo, por meio de soldagens à Laser(Grupo 1) e a TIG (Grupo 2), para confecção das amostras. Em seguida, sobre um modelo fotoelástico foram parafusadas as estruturas metálicas com torque manual de 20 Ncm, levadas ao polariscópio circular e submetidas a fotografias digitais padronizadas .Resultados: foi constatada a presença de tensões em ambos os grupos, contudo, a solda TIG exibiu maior número de franjas entre os implantes e nas cervicais distais. Conclusão: a estrutura confecciona por soldagem a Laser gerou menos tensões ao redor dos implantes que a confeccionada por soldagem a TIG para as infraestruturas de Co-Cr.


Aim: evaluate by using photoelasticity, the influence of laser welding or TIG welding of cylindrical rods of Cobalt-Chromium in the generation of tensions around implants. Methodology: using a working model with two screw implants, Cobalt-Chrome frameworks were made by laser welding method (Group 1) and TIG method(Group 2). Then, on a photoelastic model were bolted steel structures with manual torque of 20 Ncm, put to the circular polariscope and subjected to standardized digital photographs.Results: confirmed the presence of tensions in both groups, however, the TIG welding exhibited higher number of fringes between the implants and the distal neck. Conclusion: laser welding framework has generated less tension on the implants that the TIG welding for Cobalt-Chrome framework.


Subject(s)
Bone Screws , Dental Implants , Lasers , Chromium Alloys/chemistry , Dental Soldering/methods , Dental Prosthesis Design , Dental Stress Analysis , Dental Implantation/methods , Materials Testing , Reproducibility of Results , Time Factors , Tungsten/chemistry
3.
Braz. dent. j ; 23(6): 686-691, 2012. ilus, tab
Article in English | LILACS | ID: lil-662427

ABSTRACT

The aim of this study was to assess the effect of different plasma arc welding parameters on the flexural strength of titanium alloy beams (Ti-6Al-4V). Forty Ti-6Al-4V and 10 NiCr alloy beam specimens (40 mm long and 3.18 mm diameter) were prepared and divided into 5 groups (n=10). The titanium alloy beams for the control group were not sectioned or subjected to welding. Groups PL10, PL12, and PL14 contained titanium beams sectioned and welded at current 3 A for 10, 12 or 14 ms, respectively. Group NCB consisted of NiCr alloy beams welded using conventional torch brazing. After, the beams were subjected to a three-point bending test and the values obtained were analyzed to assess the flexural strength (MPa). Statistical analysis was carried out by one-way ANOVA and Tukey's HSD test at 0.05 confidence level. Significant difference was verified among the evaluated groups (p<0.001), with higher flexural strength for the control group (p<0.05). No significant differences was observed among the plasma welded groups (p>0.05). The NCB group showed the lowest flexural strength, although it was statistically similar to the PL 14 group (p>0.05). The weld depth penetration was not significantly different among the plasma welded groups (p=0.05). Three representative specimens were randomly selected to be evaluated under scanning electron microcopy. The composition of the welded regions was analyzed by energy dispersive X-ray spectroscopy. This study provides an initial set of parameters supporting the use of plasma welding during fabrication of titanium alloy dental frameworks.


O objetivo deste estudo foi avaliar o efeito de diferentes parâmetros de solda a plasma verificando a resistência flexural de barras de liga de titânio (Ti-6Al-4V). Quarenta espécimes de Ti-6AL-4V e dez espécimes de liga de NiCr foram preparados (40 mm de altura e 3,18 mm de diâmetro) e divididos em 5 grupos (n=10). As barras de liga titânio do grupo controle não foram seccionadas e nem submetidas a processo de soldagem. Os grupos PL10, PL12 e PL14, continham barras de titânio seccionadas e soldadas com uma corrente de 3 A por períodos de 10,12 e 14 ms, respectivamente. O grupo NCB consistiu de barras de liga de NiCr soldadas pelo método de brasagem convencional. Em seguida as barras foram submetidas ao teste de flexão de três pontos e os valores obtidos foram transformados em resistência flexural (MPa). Análise estatística foi realizada usando ANOVA de fator único e o teste Tukey com o nível de significância de 0,05. Diferença estatística foi verificada entre os grupos avaliados (p<0,001), com os maiores valores pra o grupo controle. Não foram encontradas diferenças entre os grupos de solda plasma (p>0,05). O grupo NCB apresentou os menores valores de resistência flexural embora tenha sido estatisticamente semelhante ao grupo PL14. Não houve diferença significante na profundidade de penetração entre os grupos de solda plasma (p=0,05). Três espécimes representativos foram aleatoriamente selecionados para serem avaliados por meio de microscopia eletrônica de varredura. A composição das regiões soldadas foi verificada por meio de espectroscopia por energia dispersiva. Este estudo fornece informações iniciais de parâmetros para permitir a utilização de soldagem plasma durante a fabricação de estruturas em liga de titânio.


Subject(s)
Humans , Dental Alloys/chemistry , Dental Soldering/methods , Plasma Gases/chemistry , Titanium/chemistry , Argon/chemistry , Chromium Alloys/chemistry , Dental Soldering/instrumentation , Materials Testing , Microscopy, Electron, Scanning , Pliability , Spectrometry, X-Ray Emission , Stress, Mechanical , Surface Properties , Welding/instrumentation , Welding/methods
4.
J. appl. oral sci ; 19(4): 301-305, July-Aug. 2011. ilus
Article in English | LILACS | ID: lil-599753

ABSTRACT

Titanium reacts strongly with elements, mainly oxygen at high temperature. The high temperature of titanium laser welding modifies the surface, and may interfere on the metal-ceramic tensile bond strength. OBJECTIVE: The influence of laser welding on the titanium-ceramic bonding has not yet been established. The purpose of this in vitro study was to analyze the influence of laser welding applied to commercially pure titanium (CpTi) substructure on the bond strength of commercial ceramic. The influence of airborne particle abrasion (Al2O3) conditions was also studied. MATERIAL AND METHODS: Forty CpTi cylindrical rods (3 mm x 60 mm) were cast and divided into 2 groups: with laser welding (L) and without laser welding (WL). Each group was divided in 4 subgroups, according to the size of the particles used in airborne particle abrasion: A - Al2O3 (250 µm); B - Al2O3 (180 µm); C - Al2O3 (110 µm); D - Al2O3 (50 µm). Ceramic rings were fused around the CpTi rods. Specimens were invested and their tensile strength was measured at fracture with a universal testing machine at a crosshead speed of 2.0 mm/min and 200 kgf load cell. Statistical analysis was carried out with analysis of variance and compared using the independent t test (p<0.05). RESULTS: Significant differences were found among all subgroups (p<0.05). The highest and the lowest bond strength means were recorded in subgroups WLC (52.62 MPa) and LD (24.02 MPa), respectively. CONCLUSION: Airborne particle abrasion yielded significantly lower bond strength as the Al2O3 particle size decreased. Mechanical retention decreased in the laser-welded specimens, i.e. the metal-ceramic tensile bond strength was lower.


Subject(s)
Air Abrasion, Dental/methods , Ceramics/chemistry , Dental Bonding/methods , Dental Soldering/methods , Lasers , Titanium/chemistry , Analysis of Variance , Materials Testing , Microscopy, Electron, Scanning , Metal Ceramic Alloys/chemistry , Particle Size , Surface Properties , Tensile Strength
5.
Article in English | IMSEAR | ID: sea-140090

ABSTRACT

Context: Alloys have been considered to be of paramount importance in the field of prosthodontics. Long span prosthesis may often require joining of one or more individual castings to obtain better fit, occlusal harmony and esthetics in comparison to one-piece casting. Aim: This study was undertaken to evaluate the mechanical properties of base metal alloys joined by two different techniques, namely, gas oxygen torch soldering and laser fusion, compared to a one-piece casting. Mechanical properties evaluated were tensile strength, percentage of elongation and hardness of the solder joint. In addition, corrosion properties and scanning electron microscopic appearance of the joints were also evaluated. Materials and Methods: The samples were prepared according to American Society for Testing Materials specifications (ASTM, E8). Specimens were made with self-cure acrylic and then invested in phosphate-bonded investment material. Casting was done in induction casting machine. Thirty specimens were thus prepared for each group and compared with 30 specimens of the one-piece casting group. Statistical Analysis Used: SPSS software (version 10.0, Chicago, IL, USA) was used for statistical analysis. ANOVA and Benferroni post hoc tests were done for multiple comparisons between the groups and within the groups for mean difference and standard error. Results: Results showed that tensile strength of the one-piece casting was higher than laser fused and gas oxygen torch soldered joints. Laser fused joints exhibited higher hardness values compared to that of gas oxygen torch soldered joints. Scanning electron microscopic examination revealed greater porosity in the gas oxygen torch soldered joints. This contributed to the reduction in the strength of the joint. Gas oxygen torch soldered joints showed less corrosion resistance when compared to laser fused joints and one-piece casting. Conclusion: Laser fusion, which is a recent introduction to the field of prosthodontics, produces joints which have properties between those of one-piece casting and the gas oxygen torch soldering.


Subject(s)
Chromium Alloys/chemistry , Corrosion , Dental Casting Technique/instrumentation , Dental Soldering/instrumentation , Dental Soldering/methods , Elastic Modulus , Electrochemical Techniques , Hardness , Humans , Lasers, Solid-State , Materials Testing , Microscopy, Electron, Scanning , Porosity , Stress, Mechanical , Surface Properties , Tensile Strength
6.
Braz. oral res ; 25(2): 103-108, Mar.-Apr. 2011. ilus, tab
Article in English | LILACS | ID: lil-583858

ABSTRACT

Widely used in dentistry, Ti-6Al-4V alloy is difficult to cast and solder, as it frequently exhibits pores inside the structure. This study was conducted to evaluate the effect of joint openings and diameters of laser-welded joints executed in Ti-6Al-4V structures on the presence of pores as checked by radiographic procedures. Sixty dumbbell rods with central diameters of 1.5, 2.0 and 3.5 mm were created from Ti-6Al-4V-wrought bars. Specimens were sectioned and welded using two joint openings (0.0 and 0.6 mm). The combination of variables created six groups (n = 10). Laser welding was executed using 360V/8ms (1.5 and 2.0 mm) and 380V/9ms (3.5 mm), with the focus and frequency set to zero. The joints were finished, polished and submitted to radiographic examination. The radiographs were visually examined for the presence of pores in the joints, qualitatively. The percentage of radiographic presence of pores was calculated without counting pores per joint. Data were analyzed using a chi-square test (α = 0.05). For the 1.5-mm specimens, the incidence of pore presence was significantly higher (p = 0.0001) when using 0.6-mm joint openings (40 percent) compared to 0.0-mm openings (0 percent). For the 2.0-mm specimens, there was no significant difference between groups (p = 0.2008). However, for the 3.5-mm specimens, the incidence of pore presence was lower (p = 0.0061) for 0.6-mm openings (50 percent) compared to 0.0-mm openings (70 percent). Therefore, laser welding of Ti-6Al-4V structures with thin diameters provides the best condition for the juxtaposition of the parts.


Subject(s)
Dental Soldering/methods , Porosity , Radiography, Dental , Titanium/chemistry , Chi-Square Distribution , Dental Casting Technique , Dental Materials/chemistry , Lasers , Materials Testing , Surface Properties
7.
Bauru; s.n; 2011. 142 p. ilus, tab, graf.
Thesis in Portuguese | LILACS, BBO | ID: biblio-865840

ABSTRACT

Com disseminação dos implantes osseointegrados na pratica clinica a ocorrência de complicações mecânicas tornam-se comuns, causando problemas para pacientes e profissionais. O objetivo deste estudo foi comparar o grau de rotação de parafusos de titânio (grau 5), durante testes de torque, re-torque e os valores de destorque (Ncm), sobre infra-estruturas fundidas em monobloco, soldadas com solda TIG e solda Convencional, a partir de abutments tipo UCLA com cinta usinada em Co-Cr. Um dispositivo leitor da quantidade de graus foi especialmente desenvolvido para este estudo, juntamente com um software. Seis implantes Titaniun Fix de 3,75 mm de diâmetro e 13 mm de comprimento e hexágono externo foram montados na base de um dispositivo e diretamente sobre eles foram obtidos os padrões para fundição dos corpos de prova. Para os grupos que foram submetidos a soldagem os corpos foram montados à análogos de implantes Titaniun Fix, e vazados blocos de gesso especial tipo IV (Durone) para serem seccionados e fundidos. Cada corpo de prova foi formado por dois abutments tipo UCLA com cinta em Co-Cr, interligados por uma barra acrílica. Foram obtidos 10 corpos de prova para cada grupo e 60 parafusos de titânio (Grau 5- Titaniun Fix) foram usados para os testes. Obteve-se então a medição do ângulo criado durante o aperto e re-aperto dos parafusos, sendo o re-aperto realizado após 10 minutos do aperto inicial, ambos sob torque de 30Ncm. Após o procedimento de re-aperto, o valor de destoque era imediatamente aferido e anotado em Ncm, possibilitando avaliar a quantidade de torque retido pelo parafuso após o procedimento, sendo esta seqüência realizada 3 vezes para cada corpo de prova. Sendo a análise estatística realizada para essa comparação (ANOVA) Análise de Variância a um critério de classificação, o teste Tukey, para verificar se havia diferença estatística entre os grupos. Os resultados revelaram que durante os procedimentos de torque (aperto), os...


With the spread of osseointegrated implants in clinical practice the incidence of mechanical complications have become common, causing problems for patients and professionals. The aim of this study was to compare the degree of rotation of titanium screws, during testing of torque, re-torque and destorque values (Ncm) in one-piece casting infrastructures, welded with TIG and Conventional welding, from UCLA strap machined Cr-Co abutments. A reader device for the number of degrees has been specially developed for this study, together with a software. Titaniun Fix implants (n=6) of 3.75mm in diameter and 13mm in length and external hexagon were mounted at the base of a device and they were obtained directly from the casting patterns of the specimens. Groups that were subjected to welding were mounted to the implant analogues, submitted to special plaster type IV (Durone) blocks. Each sample was formed by two UCLA type abutments with strap on Co-Cr, connected by an acrylic bar. It were obtained 10 specimens for each group and 60 titanium screws (Grade 5 - Titaniun Fix) were used for testing. The measurement of the angle created during tightening and re-tightening the screws, and re-grip performed 10 minutes after the initial torque, both under torque 30Ncm were obtained. After re-tightening procedure, the value of destoque was immediately measured and recorded in Ncm, to evaluate the amount of torque by the screw retained after the procedure, being this sequence performed three times for each specimen. The statistical analysis used were, analysis of variance (1 way - ANOVA) and the Tukey test to see whether there were differences between the groups. The results revealed that during the procedures of torque (tightening), the screws used in the one-piece infrastructure castings showed a higher degree of rotation (56,12°) compared to the screws used on targeted infrastructure and rendered separately welded with TIG (43,2°) and Conventional welding with a mean value...


Subject(s)
Bone Screws , Dental Casting Technique , /methods , Dental Soldering/methods , Analysis of Variance , Chromium Alloys/chemistry , Materials Testing , Rotation , Time Factors , Torque
8.
Rio de Janeiro; s.n; 2009. 69 p. ilus, tab, graf.
Thesis in Portuguese | LILACS, BBO | ID: lil-533494

ABSTRACT

O objetivo deste trabalho foi comparar, por meio de teste de microdureza e técnicas de caracterização metalúrgica, que inclui a metalografia, microscopia óptica, microscopia eletrônica de varredura (MEV) e espectroscopia por dispersão de energia (energy dispersive spectroscopy – EDS), propriedades mecânicas e metalúrgicas de juntas soldadas pelos métodos TIG e brasagem em uma liga odontológica à base de Ni-Cr (FIT-CAST SB). As regiões estudadas em cada amostra foram o metal de base (MB), a zona termicamente afetada (ZTA) e a zona de fusão (ZF). Foram confeccionados 40 corpos-de-prova cilíndricos, em forma de bastão, com 2,5mm de diâmetro e 18,0mm de comprimento, obtidos apartir de fundição odontológica por centrifugação (técnica da cera perdida). Foram separados vinte cilindros para cada técnica, que após a soldagem formaram grupos de dez amostras para cada procedimento. A microestrutura do MB apresentou-se como uma matriz de uma solução sólida à base de Ni-Cr contendo um típico arranjo dendrítico de estrutura eutética. A liga apresentou precipitados metálicos na região interdendrítica da estrutura eutética. A análise química semi-quantitativa obtida através da técnica de EDS apresentou resultados compatíveis com a composição química quantitativa fornecida pelo fabricante da liga. Na brasagem, o MB e a ZF apresentaram microestruturas distintas. A ZF apresentou uma morfologia dendrítica grosseira com a presença de precipitados e porosidades. A análise química semi quantitativa por EDS da ZF mostrou-se bastante semelhante aos resultados obtidos para o MB...


The purpose of this study was to compare, by means of microhardness testing and metallurgical characterization techniques as metallography, optical microscopy, scanning electron microscopy (SEM) and energy dispersion spectroscopy (EDS), mechanical and metallurgical properties of welded joints by TIG and brazing methods in a dental alloy based on Ni-Cr (FIT-CAST SB). The studied regions in each sample were the base metal (MB), the heat affected zone (ZTA) and the fusion zone (ZF). Forty cylindrical bodies-of-proof, stick-shaped, with 2.5mm diameter and 18.0mm in length were made from dental casting by centrifugation (lost wax technique). Twenty cylinders were used for each technique, which formed, after the welding, groups of ten samples for each procedure. The microstructure of the MB is presented as a matrix of a solid solution based on Ni-Cr with a typical dendritic arrangement of eutectic structure. The alloy presented metallic precipitates in the interdendritic region of the eutectic structure. The semiquantitative chemical analysis obtained by EDS technique showed results consistent with the quantitative chemical composition provided by the alloy manufacturer. In the brazing method, the MB and ZF showed different microstructures. The ZF showed a rough dendritic morphology with the presence of precipitates and porosities. The semiquantitative chemical analysis by EDS of the ZF had very similar results to those obtained for the MB...


Subject(s)
Chromium Alloys , Nickel , Dental Soldering/instrumentation , Dental Soldering/methods , Tungsten , Hardness Tests , Microscopy , Microscopy, Electron, Scanning
9.
Braz. dent. j ; 20(5): 403-409, 2009. tab, ilus
Article in English | LILACS | ID: lil-537547

ABSTRACT

The aim of this study was to analyze the shear bond strength between commercially pure titanium, with and without laser welding, after airbone-particle abrasion (Al2O3) and 2 indirect composites. Sixty-four specimens were cast and divided into 2 groups with and without laser welding. Each group was divided in 4 subgroups, related to Al2O3 grain size: A - 250 µm; B - 180 µm; C- 110 µm; and D - 50 µm. Composite rings were formed around the rods and light polymerized using UniXS unit. Specimens were invested and their shear bond strength at failure was measured with a universal testing machine at a crosshead speed of 2.0 mm/min. Statistical analysis was carried out with ANOVA and Tukey's test (á=0.05). The highest bond strength means were recorded in 250 µm group without laser welding. The lowest shear bond strength means were recorded in 50 µm group with laser welding. Statistically significant differences (p<0.05) were found between all groups. In conclusion, airborne particle abrasion yielded significantly lower bond strength as the Al2O3 particle size decreased. Shear bond strength decreased in the laser welded specimens.


O objetivo deste estudo foi analisar a força de união entre o titânio comercialmente puro com solda e sem solda modificado por partículas de óxido de alumínio (Al2O3) e duas resinas indiretas. Um total de 64 espécimes foram fundidas e divididas em dois grupos sem solda e com solda a laser. Cada grupo foi novamente divididos em 4 subgrupos, de acordo com o tamanho de partículas de óxido de alumínio utilizado: A - Al2O3 (250 µm); B - Al2O3 (180 µm); C- Al2O3 (110 µm); D - Al2O3 (50 µm). Anéis de resina foram polimerizados ao redor das hastes de titânio no equipamento UniXS. Os espécimes foram embutidos em gesso e a força de união foi mensurada com auxílio da máquina de ensaios universais. ANOVA e teste de Tukey (p<0,05) foram utilizados para análise estatística. Os maiores valores de força de união foram registrados no grupo de 250 µm sem solda a laser. Os menores valores foram registrados para o grupo de 50 µm com solda a laser. Alterações estatisticamente significantes foram observadas entre todos os grupos (p<0,05). As forças de união diminuíram significantemente com a diminuição dos tamanhos das partículas de óxido de alumínio. A força de união diminuiu nas amostras que receberam a solda a laser.


Subject(s)
Composite Resins , Dental Alloys , Dental Soldering/methods , Light-Curing of Dental Adhesives , Titanium , Air Abrasion, Dental , Analysis of Variance , Dental Stress Analysis , Lasers , Materials Testing , Particle Size , Shear Strength , Statistics, Nonparametric , Welding/methods
10.
Odonto (Säo Bernardo do Campo) ; 16(32): 39-46, jul.-dez. 2008. ilus, tab, graf
Article in Portuguese | LILACS, BBO | ID: lil-542928

ABSTRACT

O efeito da soldagem e termociclagem na união metalo-cerâmica foi avaliado pela fundição de sessenta barras metálicas em NiCr nas dimensões estabelecidas para o teste de flexão (ISO 9693:1999E). Destas, 20 barras formaram o grupo controle (GC) e 40 foram segmentadas: 20 unidas por brasagem (GB) e 20 soldadas a laser (GL). Uma camada de 1,0mm de cerâmica foi aplicada sobre as barras, as quais receberam (0,1mm de opaco e 0,9mm de dentina) na sua área central e inferior. A área total testada foi de 20mm com carga central. Os tratamentos de superfície do metal, a temperatura e tempos de queima da cerâmica foram os recomendados pelos fabricantes. A metade dos corpos-de-prova foi termociclada (GCT, GBT e GLT). Todos os corpos-de-prova foram submetidos ao teste de flexão de três pontos com célula de carga de 10Kg e velocidade 1,5±0,5mm/min em uma máquina de ensaios universal, e as cargas máximas até a falha inicial foram anotadas. Os dados foram submetidos à análise de variância e ao teste de Tukey. Não houve diferença significante estatisticamente com relação à força máxima até a falha de união metalo-cerâmica para os grupos GB (10,55±1,37N), GL (9,87±1,22N) e grupo controle GC (14,5±2,11N), que apresentou a força mais alta até falha, estatisticamente significante em relação aos demais grupos, com p=0,001. Para a termociclagem, não houve diferença significativa estatisticamente dentro de todos os grupos estudados. Após o teste, um corpo-de-prova de cada um dos grupos, foi observado por MEV associado ao EDX.


Among these ones, 20 bars formed the control group (CG) and 40 were divided: 20 were attached by the use of brazing (BG) and 20 were laser welded (LG). A 1,0mm ceramic layer (0,1mm of opaque ceramics and 0,9mm of dentine ceramics) was applied over the bars, on its central and bottom area. The total area tested had 20mm2, with central load. The metal surfaces treatments, the temperature, and the times of ceramics coccion were recommended by the manufacturers. Half of the specimens were thermocycled (CGT, BGT, LGT). All the specimens underwent the three point bending test with a 10-kilo load cell and speed of 1,5±0,5mm/min in an universal testing machine and the maximum load up to initial failure was marked. Data underwent statistical analysis (ANOVA and Tukey Test). There was no relevant static difference concerning the maximum load to metal-ceramic failure of the groups BG (10,55±1,37N) and LG (9,87±1,22N), but CG had the highest load up to failure (14,5±2,11N), statistically relevant, of all the groups, with p=0,001. When it comes to thermocycling, there were no relevant differences statistically, among all the studied groups. After the test, one specimen of each one of the groups was observed by MEV associated to EDX.


Subject(s)
Chromium Alloys , Dental Alloys , Dental Materials , Metal Ceramic Alloys/chemistry , Materials Testing , Dental Soldering/methods
11.
J. appl. oral sci ; 16(5): 328-335, Sept.-Oct. 2008. ilus, tab
Article in English | LILACS | ID: lil-495136

ABSTRACT

The aim of this study was to compare the mechanical strength of different joints made by conventional brazing, TIG and laser welding with and without filling material. Five standardized joining configurations of orthodontic wire in spring hard quality were used: round, cross, 3 mm length, 9 mm length and 7 mm to orthodontic band. The joints were made by five different methods: brazing, tungsten inert gas (TIG) and laser welding with and without filling material. For the original orthodontic wire and for each kind of joint configuration or connecting method 10 specimens were carefully produced, totalizing 240. The fracture strengths were measured with a universal testing machine (Zwick 005). Data were analyzed by ANOVA (p=0.05) and Bonferroni post hoc test (p=0.05). In all cases, brazing joints were ruptured on a low level of fracture strength (186-407 N). Significant differences between brazing and TIG or laser welding (p<0.05, Bonferroni post hoc test) were found in each joint configuration. The highest fracture strength means were observed for laser welding with filling material and 3 mm joint length (998 N). Using filling materials, there was a clear tendency to higher mean values of fracture strength in TIG and laser welding. However, statistically significant differences were found only in the 9-mm long joints (p<0.05, Bonferroni post hoc test). In conclusion, the fracture strength of welded joints was positively influenced by the additional use of filling material. TIG welding was comparable to laser welding except for the impossibility of joining orthodontic wire with orthodontic band.


Subject(s)
Dental Stress Analysis , Dental Soldering/methods , Orthodontic Appliance Design , Orthodontic Wires , Dental Alloys , Lasers, Solid-State , Materials Testing , Tensile Strength , Tungsten , Welding/methods
12.
Rev. Clín. Ortod. Dent. Press ; 6(5): 102-107, out.-nov. 2007.
Article in Portuguese | LILACS, BBO | ID: lil-495629

ABSTRACT

O objetivo deste artigo foi realizar uma revisão de literatura sobre o processo de soldagem autógena em Ortodontia. A soldagem autógena, muito presente no cotidiano clínico, viabiliza a união de dispositivos, principalmente de aço inoxidável, necessários à realização da mecânica ortodôntica. A técnica foi descrita juntamente com as modificações apresentadas pelos componentes envolvidos no processo. Comparou-se, também, tal procedimento com a soldagem heterógena, evidenciando-se uma menor ocorrência de alterações estruturais nos elementos envolvidos, bem como uma menor subordinação da técnica à destreza do operador.


Subject(s)
Stainless Steel , Metallurgy , Dental Soldering/methods
13.
Rev. Clín. Ortod. Dent. Press ; 6(4): 42-49, ago.-set. 2007. ilus, tab
Article in Portuguese | LILACS, BBO | ID: biblio-856195

ABSTRACT

Objetivou-se neste trabalho realizar uma revisão de literatura sobre o processo de soldagem em Ortodontia, pelo fato do mesmo só ser conhecido sob um enfoque empírico. A técnica de soldagem é universalmente aceita e de resultados clinicamente eficazes. Descreveu-se não somente a técnica em si, mas também o comportamento de todos os componentes qua a interagem durante o procedimento de soldagem, incluindo alterações atômicas, mecânicas e físicas. Abordou-se o processo de soldagem a ouro por ter sido o percursor em Ortodontia de todas as outras técnicas envolvendo solda, além de demandar grande habilidade manual, por ser um procedimento de extrema complexidade de execução. Comparou-se também tais procedimentos com a soldagem autógena, avaliando-se vantagens e desvantagens clínicas de seu emprego. Não foram observadas alterações significativas nas características físico-estruturais dos elementos a serem soldados heteroginamente, não havendo assim, nenhuma desvantagem relevante em relação à soldagem autógena


Subject(s)
Gold , Metallurgy , Silver , Dental Soldering/methods
14.
Braz. dent. j ; 17(1): 20-23, 2006. tab, graf
Article in English | LILACS | ID: lil-430127

ABSTRACT

O processo de soldagem de metais e ligas é importante para a Odontologia para fabricação de próteses dentárias. Existem atualmente diversos métodos utilizados na soldagem de metais e ligas. O objetivo deste trabalho foi avaliar a solda do Titânio e ligas de Ni-Cr e Co-Cr usando o sistema TIG e o laser Nd:YAG utilizando o teste de resistência à flexão. Sessenta corpos-de-prova cilíndricos foram confeccionados (20 de cada material), seccionados ao meio e soldados por TIG ou por laser de Nd:YAG, com e sem um material da preenchimento. Quaro grupos foram formados (n=15). I: soldagem a laser de Nd:YAG; II: soldagem à laser usando um material de preenchimento; III: soldagem com TIG; IV (controle): sem soldagem (corpos-de-prova intactos) As amostras foram submetidas a ensaios de flexão e os resultados analisados pela ANOVA a um critério. Houve diferença estatisticamente significante entre o metal e as ligas íntegras (p<0.001), sendo a liga do Co-Cr o mais resistente à deflexão. Ao se comparar os diferentes processos de soldagem, diferença estatisticamente significante (p<0.001) foi encontrada entre a solda TIG e o laser de Nd:YAG e entre este e o laser mais o material de preenchimento. Conclui-se que a soldagem com TIG apresentou melhores resultados que a soldagem com o laser de Nd:YAG para os três materiais testados.


Subject(s)
Chromium Alloys/chemistry , Dental Soldering/methods , Titanium/chemistry , Analysis of Variance , Chromium Alloys/radiation effects , Titanium/radiation effects
15.
s.l; s.n; abr.1991. 268 p. ilus.
Thesis in Spanish | LILACS | ID: lil-111235

ABSTRACT

Se trata de evaluar y comparar los valores de resistencia tradicional final (R.T.F) obtenidos a partir de uniones soldadas producidas por dos métodos: el que usa energia infraroja focalizada (infrarojo) y el método convencional del mechero (aire-gas); usando tres aliaciones de paladio y de acuerdo a recomendaciones de los fabricantes. Las uniones soldadas producidas con la técnica de infraroja se evaluaron en resistencia tradicional, prioridad y humectabilidad de la aliación matriz por parte de la soldadura; demostrandose finalmente que las uniones soldadas usando el método infrarojo, producen resultados clínicos aceptables; pero que a la vez las producidas por el método convencional del soplete son más resistentes al 5% del nivel de confianza. Se vió también que la presencia de un fundente es indispensable en las soldaduras de aliaciones basadas en paladio, y que los regímenes de escurrimiento de combinaciones de productos no se relacionan bien con los resultados en valores RTF y porosidad


Subject(s)
Dental Alloys , Dental Soldering/methods , Palladium